Urnex Cafiza
Cleaning tablets for coffee machines
Cleaning tablets for espresso and pour over coffee machines, both commercial and home.
Concentrated formula eliminates residue in group heads, valves, and lines.
- Eliminates coffee residue and oils from espresso machine groupheads, valves and lines.
- Keeps screens and filters clear for even extraction.
- Can also be used to make a soaking solution to clean portafilters, baskets, screens, and other parts.
- Formulated for optimal balance of solubility and foaming.
- Odorless.
- OMRI NSF certified for organic use
For Use on Automatic Espresso Machines (If the machine has a cleaning program)
Insert one Espresso Machine Cleaning Tablet in specified machine opening.
If the machine does not have a programmed cleaning cycle, but has a pre-ground coffee or bypass chute
1. Put one Espresso Machine Cleaning Tablet in the pre-ground coffee chute and place a cup under the coffee spout.
2. Press the button corresponding to brewing with pre-ground coffee.
3. When half a cup of water has been discharged, switch the appliance off for 5 minutes to let the solution take effect inside of the machine.
4. Switch the appliance back on again to end the cycle.
5. Repeat this cycle a minimum of 3 additional times to rinse, but do not add additional tablets to the machine (to ensure that all cleaning solution has come out the machine).
6. Remove the coffee dispensing unit and rinse it carefully using clean water.
7. Before using the appliance again, prepare two cups of coffee, by pressing the button corresponding to brewing with pre-ground coffee
- Cafiza is cleaning and removing coffee oils. It is not a descaler. For descaling use Urnex Dezcal.
- For cleaning the Milk reservoir and lines use Urnex Rinza tablets.
How to Backflush an espresso machine
- Insert blind filter in portafilter and add 1 Cafiza Tablet.
- Insert portafilter into group head. Activate brew cycle for 10 seconds. Stop 10 seconds. Repeat 5 times.
- Remove portafilter and activate brew cycle and rinse portafilter in stream of water from group head.
- Reinsert portafilter without cleaning powder. Activate brew cycle for 10 seconds. Stop 10 seconds. Repeat 5 times.
- Replace blind filter with standard basket. Make a cup of espresso to remove any traces of cleaner.
- Discard espresso - do not drink.
How to Clean Parts and Accessories
- Create a soaking solution using 1 tablet for every liter of hot water.
- Place dirty part in the cleaning solution. If soaking a portafilter, do not submerge the handle.
- Allow the part to soak for 30 minutes.
- Remove the part and rinse with fresh water.